Accessories

Amana PTAC Wall Sleeve
Size: 14 1/8" (D) x 42" (W) x 16 1/16" (H)
Insulated, stonewood beige metal sleeves with industry standard dimensions are shipped with a weather board for useduring construction

The WS900D is an industry-standard depth of 14 1/8”
The extra-deep sleeves can be custom ordered starting at 16” to 24” (D) in 1” increments Sleeves may be shipped separately to allow for installation during construction

Wall Sleeve

SKU: 18578

Wall Sleeve

SKU: 18578

14-1/8” (D) x 42” (W) x 16-1/16” (H) Our insulated, stonewood beige metal sleeves
with industry standard dimensions are shipped
with a weather board for use during construction.  

The WS900D is an industry-standard depth of
14-1/8”. The extra-deep sleeves can be custom
ordered starting at 16” to 24” (D) in 1” increments.

Sleeves may be shipped separately to allow for
installation during construction.

WS900D Standard 14-1/8" Depth
WSD900DID Sleeve with Internal Drain

WS9**D1
(** = " Deep)

Extra-Deep (16" to 24")

 

Available in stamped-aluminum, extruded aluminum, or in a one piece molded versions for use with a WS900D wall sleeve.

SGK —

Standard stamped aluminum grille.Available with mill finish or a baked-on paint in Stonewood Beige.

  • B (Mill Finish)
  • TB (Stonewood Beige) 

AGK —

Extruded aluminum architectural grille. Available with anodized aluminum finish and a baked-on paint finish for durability. Choose from 3 stock colors or a custom color:

  • CB (Clear Anodized)
  • DB (Dark Brown/Bronze)
  • TB (Stonewood Beige)
  • WB (White)
  • SB (Special/Custom Colors)

PGK —

One-piece injection molded grille using a polymer blend of engineered thermoplastic high-impact strength material with chemical resistance and an exterior UV protective coating. Choose from 3 stock colors: 

  • DB (Dark Brown/Bronze)
  • TB (Stonewood Beige)
  • WB (White)

Sub-base Kit

SKU: 18580

Sub-base Kit

SKU: 18580

Required for 265V unit.

The fully skirted sub-base conceals wiring
and provides strong support. Plug-in
receptacle and field-wiring access speed
installation.

Electrical accessories meet NEC
requirements; can be installed in the unit
sub-base.

Sub-base may be installed onto wall sleeve
either before or after sleeve installation.
Minimum clearance between wall sleeve
bottom and finished floor is 3 3/4”;
maximum height clearance from bottom
of wall sleeve and finished floor is 5”.

Minimum clearance between wall sleeve
flange and finished wall is 2 3/4”.

PTSB320E

230/208V

15/20A

PTSB330E

230/208V

30A

PTSB420E

265V

15/20A

PTSB430E

265V

25A

PTSB000E

Non-Electrical

 

Charcoal Filter Kit  10 PACK

Amana DigiSmart  DT01G

Circuit Breaker Kit

SKU: 18582

Circuit Breaker Kit

SKU: 18582

Circuit Breaker Kit

 

  • For use on non-baffled grilles.
  • Includes 2 air-deflection baffles that can be mounted on the condenser coil to direct air toward the center and away from the inlet. This prevents the recirculation of hot condenser air, maintaining unit cooling and heating capacity and unit efficiency.
  • Use the baffles when an older unit is being replaced and when the existing grille does not have deflector baffles.
  • Any existing baffles must be removed to install this kit.

 

The condensate drain attaches to the wall sleeve base pan or the wall sleeve’s outside corners for controlled indoor/outdoor disposal of condensate.

Install the wall sleeve in the wall before an indoor/outdoor drain kit is installed.

 Heat Pump Only

This kit removes most condensate generated during heat pump operation by transferring it to the indoor coil. The
warm coil surface and warm room air evaporate the condensate, while adding humidity to the room.

This kit decreases the sensible heating capacity of the unit and is not intended for use in seacoast or corrosive environments.

NOTE:

Under some high-humidity operating conditions, this kit may not be able to remove all condensate produced, and
condensate could drip from the outside of the wall sleeve.

To prevent this, a drain system (including factory-approved drain kit for the wall sleeve) should be installed.

When two adjacent rooms need to be conditioned, these kits transfer air between rooms (airflow distribution can be adjusted from 65/35 to 80/20).

Refer to EDK02B (Extension Duct Kit) and TDK02 (Duct Extension Kit- Terminal Duct & Grille) for complete installation.

Includes a grille and sleeve for fitting a duct extension through the wall.

Refer to MDK02B (Duct Extension - Main) and EDK02B (Extension Duct) for complete installation.

   

 

When two adjacent rooms need to be air conditioned, these kits transfer air from one room to another, yet allow different airflows for the rooms (airflow distribution can be adjusted from 65/35 to 80/20).

Must use with MDK02B (Duct Kit - Main).

EDK02B Extension Duct Kit

 

Fuse Holder Kit

SKU: 18590

Fuse Holder Kit

SKU: 18590

Installed directly in the chassis or in the optional subbase. (Fuse Kit and Fuse installed on 265-volt unit).

Fuses are not included in the kits, but they may be purchased from the manufacturer.

Meets NEC requirements.

FHK315C 230/208V 15A
FHK320C 230/208V 20A
FHK330C 230/208V 30A

 

For 265V units.

Directs wire to the unit when it is not ideal to use the standard unit sub-base or unit power cord.

A junction box provides a protected enclosure for electrical connections (required by some electrical codes) and can be mounted before or after the wall sleeve is mounted and the unit chassis is installed in the wall sleeve.

The junction box is furnished with approximately 3½’ of ½” flexible steel conduit and a 90° conduit clamp for securing the conduit to the unit cabinet at the electrical access opening.

Follow national or local codes regarding flush, surface or recessed mounting of boxes.

PTPWHWK4 Hard Wire Kit

 

These kits fit all units, allowing the addition of hydronic water or hydronic steam heat to cooling and heating units when a central boiler is not available.

Featuring left- or right-hand piping, the kit uses the existing unit chassis front, enclosing all plumbing and coils while retaining easy access to controls.

Chassis can slide out for easy service without removing hydronic plumbing.

Max. steam pressure is 5 PSIG, based on ARI Rating conditions of 70 °F entering air temperature and 2 PSIG steam pressure.

HWK03 Hydronic Water Kit
HVK03 Hydronic Steam Kit

 

Leveling Legs LL2C

SKU: 18593

Leveling Legs LL2C

SKU: 18593

Optional leveling legs fit the wall sleeve to provide front support and leveling, if required.

These legs cannot be used for 0" floor clearance.

LL2C

Leveling Legs

 

This kit provides ten replacement escutcheons, allowing the removal of control knobs and graphics no longer required when a wall thermostat is used to control the unit. The kit also includes 80 jumper wires and wire nuts to provide connection from the 14-pin terminal strips on the PTAC control boards to manufacturer-approved remote thermostats and one of the following board features:

  • Emergency Hydronic Heat*
  • Load Shedding*
  • Front Desk Control*
  • Transfer Fan (see installation instructions for details)

*If other than a “dry switch” is used in connecting these features, consult manufacturer before proceeding.

REK10B

Low Voltage Kit

 

A power disconnect switch can be installed in the optional Standard Subbase or in the junction box of the Hard Wire Kit.

The switch provides a Power On/Off function as required by some electrical codes.

Meets NEC requirements.

 

 

 

 

 

This kit employs a specially designed fan to increase outdoor air CFM (up to 95 CFM) through the vent during fan operation.

Designed for applications where outside air ventilation is imperative.

The power door is part of this kit.

 

 

 

 

 

This automatically opens or closes the vent door depending on fan operation (opens when fan is operating; closes when fan is off).

This allows ventilation with outside air during fan operation and saves energy during outside temperature drops.

PDK3A

Power Door Kit 230/208V

PDK4A

Power Door Kit 265V

 

Remote Temperature Sensor  RTS02

Helps keep dirt and lint out of the air and off the coil, increasing unit efficiency.

Located in the front panel of the unit, the easily removable filter can be pulled out, cleaned and reinserted in up to four positions.

FK10A

Replacement Filter Kit “A” Series (10 Pack)

FK10B

Replacement Filter Kit “B: Series (10 Pack)

 

In conjunction with the tamper-resistant front, the installation of Amana® brand security key locks prevents tampering
with the controls used to set temperature, heating and cooling functions. 

U.L. approved for institutional use only.

KL03B

Security Key Lock

 

A variety of wired thermostats may be used with the Amana® PTAC. Seven standard wired thermostats are offered as listed at right.

All of these can be connected to the PTAC through a low voltage connection.

The Amana® DigiSmart™ PTAC also offers a wireless remote thermostat.

Any thermostats other than those listed at right or the DigiSmart thermostat must be submitted to Goodman for approval prior to use.

Model

Heat Stages

Cool Stages

Display

Type

C5200609

1*

1

Mech.

Manual

D9945801

2**

1

Mech.

Manual

1246005/6

1*

1

Mech.

Manual

1246001

1*

1

Digital

Manual

1246003

2**

1

Digital

Manual

1246004

2**

1

Digital

Program

1241501

2**

1

Digital

Auto Change

 

Use this kit to quickly connect an Amana® remote thermostat or the front desk with jumpers and connectors.

Includes 18 pre-terminated, color-coded wires and wire-nuts - enough to connect any accessory.

  Wire Harness Kit

 

Amana Wire Harness Kit PWHK01C

Amana Low Voltage Kit (10 Pack)   REK10B

Amana Terminal Duct Kit TDK02

 

  • Wall Sleeve for 26" Series

  • Required for Through-the-Wall Installations

  • AXSVA1A-1